AV-QCNP Aurevant AV-QC Chemistry Normal & Pathological (2-Level Liquid Control)
Quality Control Materials

AV-QCNP AV-QC Chemistry Normal & Pathological (2-Level Liquid Control)

Manufacturer: Aurevant Medical Type: Quality control material – multi-analyte chemistry (liquid, 2-level) Identity: Aurevant Medical

Liquid, ready-to-use two-level (Normal and Pathological) multi-analyte quality control for routine clinical chemistry. Human-matrix based, extended open-vial stability, assayed for more than 25 common chemistry analytes. Designed by Aurevant Medical for reliable daily QC on automated and semi-automated analyzers.

No approved datasheet is available for this product yet.

Overview

The Aurevant AV-QC Chemistry Normal & Pathological is a liquid, ready-to-use two-level quality control material intended for the monitoring of precision and accuracy of routine clinical chemistry assays. The set provides a Normal (Level 1) and a Pathological (Level 2) control that together span the clinically relevant concentration ranges for more than 25 frequently measured analytes, including metabolites, enzymes, lipids, proteins and selected electrolytes.

The controls are prepared from a human serum matrix to improve commutability with patient samples. Being liquid and ready-to-use, they eliminate reconstitution steps and reduce the risk of preparation errors. After opening, the controls demonstrate extended open-vial stability when stored at 2–8 °C, supporting efficient daily QC practices.

Assayed target values and acceptable ranges are provided for each analyte on a lot-specific value sheet. The controls are designed for use with Aurevant chemistry reagents on AV-Chem series analyzers and are also suitable for other open-system clinical chemistry instruments after laboratory validation.

This product is an original Aurevant Medical quality control material manufactured under controlled conditions and intended for professional laboratory use by trained personnel.

Product name and code identify the record only; they are not a substitute for current manufacturer documentation. Confirm intended use, configuration, availability, supported applications, and all technical and commercial terms in writing before procurement.

Frequently Asked Questions

How many levels are included?

Two levels: Normal (Level 1) and Pathological (Level 2).

Is the control liquid or lyophilized?

It is a liquid, ready-to-use control. No reconstitution is required.

How many analytes are assayed?

More than 25 routine clinical chemistry analytes are typically assigned. The exact list and values are provided on the lot-specific value sheet.

What is the open-vial stability?

After opening, the controls typically remain stable for 14–30 days when stored at 2–8 °C. The exact claim is stated on the package insert and value sheet for each lot.

Is the matrix human-based?

Yes. The controls are prepared from a human serum matrix to improve commutability with patient samples.

Can these controls be used with non-Aurevant reagents?

They are optimized for Aurevant reagents on AV-Chem analyzers. Use with other reagent systems requires laboratory verification of the assigned values and suitability.

How should the controls be handled before use?

Allow the bottles to equilibrate to the appropriate temperature, mix gently by inversion, and load them onto the analyzer in the same manner as patient samples.

Request a Quote

Request model-specific availability, configuration, delivery, warranty, training, and service information.